Honeywell Searchpoint Optima Plus OPTIMAFLOWKIT – Sampling: Optima Plus Flow Housing Retrofit Kit (for converting std unit to sampling)

OPTIMAFLOWKIT is a Searchpoint Optima Plus Sampling: Optima Plus Flow Housing Retrofit Kit (for converting std unit to sampling). It is not a gas detector body and will not detect LEL on its own. Order this SKU for maintenance, calibration or mounting; the head remains a 2108N transmitter number.

OPTIMAFLOWKIT is a Sampling; see same-class SKUs in the matrix.

OPTIMAFLOWKIT Honeywell Searchpoint Optima Plus — Sampling

Part-number decode

SegmentMeaningThis SKU
FamilyHoneywell Searchpoint Optima Plus point IROptima Plus
P/NOptima Plus Flow Housing Retrofit Kit (for converting std unit to sampling)OPTIMAFLOWKIT
ClassAccessorySampling

Technical specifications

CategoryAccessory / Sampling
DescriptionOptima Plus Flow Housing Retrofit Kit (for converting std unit to sampling)
Gas—
Output—
Approvalssee description
Entries—
Enclosure—
RGC—
PrinciplePoint IR (dual source, dual beam)
Range—
Ingress随本体

Why this part number

Keep OPTIMAFLOWKIT on its own BOM line so windows, lamps, PCBs, glands and brackets can be replaced on their own cycle. Do not bury it under 2108N4000N, and do not fit XCD or XNX spares on Optima optics.

Spares and mates

OPTIMAFLOWKIT is Searchpoint Optima Plus Sampling. This SKU is a spare or accessory and needs an Optima Plus detector. Matrix: product-2698. Do not substitute Sensepoint XCD cartridges or XNX personalities.

Typical applications

Use OPTIMAFLOWKIT against installed Optima Plus points: dust barriers after deluge, flow housings on extractive loops, cups and cylinders at annual gas. Match the detector thread (M20 vs NPT) before the box ships.

Selection contrast

P/NTypeGasCertOutput
2108N5000NSamplingHydrocarbonATEX4–20 mA
2108N5000HSamplingHydrocarbonATEXHART+4–20 mA
2108N5001NSamplingEthyleneATEX4–20 mA
2108N5001HSamplingEthyleneATEXHART+4–20 mA
2108N5010NSamplingHydrocarbonATEX4–20 mA
2108N5010HSamplingHydrocarbonATEXHART+4–20 mA
2108N5100NSamplingHydrocarbonUL4–20 mA

Optima Plus family matrix

Installation and service

Isolate power before swapping OPTIMAFLOWKIT. Refit seals to the specified torque and keep M20/M25/NPT families apart. Zero and span afterwards; keep fingerprints and condensation off the optics.

FAQ

Can I fit an XCD/XNX spare instead of OPTIMAFLOWKIT?
No. Optima optics, seals and connectors are unique.
Vs Searchline Excel?
Optima is point IR; Excel is open-path.
Thread mix-ups?
Yes. Glands, plugs and adaptors split M20 / M25 / 3/4" NPT. Copy the detector nameplate.
Spares?
Use the family matrix; do not mix other IR-platform parts.
Rescale on site?
Follow the manual/ordered config; re-order if needed.

Documents

Optima Plus datasheet 1 · Datasheet 2 · On-site part-number matrix

Availability and enquiry

Availability: Not in stock — orders accepted; lead time approx. 12 weeks. Quote full P/N OPTIMAFLOWKIT, gas/range and approval.