H-D03-0002-000 | RAEGuard 2 PID Instrument
H-D03-0002-000 is a RAE Hua Rui RAEGuard 2 PID instrument kit (FGM-2002, Diffusion, 0.1–1000 ppm, ATEX/IECEx). 10–28 VDC, 4–20 mA and RS-485 Modbus, magnetic-wand service. This range disables correction factors and relays.
English-list hub: product-9019. China-list hub: product-8017. Each part number has a single HTML file.
.png)
Part-number decode
| Segment | Meaning | This SKU |
|---|---|---|
| Family | RAEGuard 2 PID / FGM-200X | H |
| Type | Instrument / accessory / consumable / spare | Instrument |
| English-list group | Instrument / Accessories / Consumables & Spares | Instrument |
| Model | FGM-2001 / FGM-2002 | FGM-2002 |
| Sampling | Diffusion / Flow-through | Diffusion |
| Range | 0.01–100 / 0.1–1000 / 1–1000 ppm | 0.1–1000 ppm |
| Approval | ATEX/IECEx, UL, Russia, China | ATEX/IECEx |
| This SKU | Kit, RAEGuard 2 PID, DIFF, 0.1 – 1000 ppm, FGM-2002, ATEX/IECEx | H-D03-0002-000 |
Technical specifications
| Category | RAEGuard 2 PID instrument kit |
|---|---|
| Model | FGM-2002 / Diffusion |
| Approval | ATEX/IECEx |
| Gas | VOC / TVOC,10.6 eV PID |
| Range | 0.1–1000 ppm |
| Resolution | 0.1 ppm |
| Power | 10–28 VDC,约 210 mA@24 V,< 5 W |
| Output | 4–20 mA + RS-485 Modbus + 三路继电器 30 VDC 2 A |
| Entry | 3/4″ NPT M |
| Mounting | 2″ pipe or wall |
| Ingress | IP65 |
| Sensor module | C01-0902-012 |
Why this part number
Order H-D03-0002-000 to lock range, sampling and approval: Kit, RAEGuard 2 PID, DIFF, 0.1 – 1000 ppm, FGM-2002, ATEX/IECEx. China D03-*-C00 kits are on product-8017.
What it mates with
H-D03-0002-000 belongs to Instrument. The kit includes the head and DigiPID.
Typical applications
Refineries, solvent recovery, coating, wastewater, power plants and ambient VOC monitoring.
Selection contrast
| P/N | Type | Description |
|---|---|---|
| H-D03-0001-000 | Instrument | Kit, RAEGuard 2 PID, DIFF, 0.01 – 100 ppm, FGM-2001, ATEX/IECEx |
| H-D03-0015-000 | Instrument | Kit, RAEGuard 2 PID, DIFF, 0.01 – 100 ppm, FGM-2001, UL |
| H-D03-0016-000 | Instrument | Kit, RAEGuard 2 PID, DIFF, 0.1 – 1000 ppm, FGM-2002, UL |
| H-D03-0005-000 | Instrument | Kit, RAEGuard 2 PID, ATEX/IECEx, 0.1 – 1000 ppm isobutylene equivalent,Flow-through |
| H-D03-0010-000 | Instrument | Kit, RAEGuard 2 PID, UL, 0.1 – 1000 ppm isobutylene equivalent,Flow-through |
| H-D03-0001-C00 | Instrument | KIT, RG 2 PID, 0.01-100 PPM, FGM-2001, CN |
| H-D03-0005-R00 | Instrument | Kit, RAEGuard 2 PID, Russia, 0.1 – 1000 ppm isobutylene equivalent |
Installation and service
Mount H-D03-0002-000 on a 2″ pipe or wall, 3/4″ NPT M entries. Power 10–28 VDC. Sensor pointing down. Flow-through water trap on inlet IN. Two-point cal with isobutylene.
FAQ
- Substitute the PID lamp?
- No. DigiPID needs the specified MARK2 10.6 eV lamp and PTFE O-ring.
- Vs RAEGuard 3?
- RG2 PID is VOC; RG3 covers CAT/NDIR/EC toxic-O₂.
- Diffusion vs Flow Through?
- Do not mix weather/pretreatment/dryer kits; those are Flow Through only.
- Which line is H-D03-0002-000?
- RAE / Honeywell RAEGuard 2 PID (FGM-2001/2002) fixed VOC.
- Hazardous-area service?
- DigiPID unplugs for off-line cal; follow site permits.
Documents
English datasheet · Combined Manual Rev H · TVOC gas table · product-9019 · product-8017