H-D03-0005-R00 | RAEGuard 2 PID Instrument
H-D03-0005-R00 is a RAE Hua Rui RAEGuard 2 PID instrument kit (FGM-2002, Flow-through, 0.1–1000 ppm, Russia). 10–28 VDC, 4–20 mA and RS-485 Modbus, magnetic-wand service. This range disables correction factors and relays.
English-list hub: product-9019. China-list hub: product-8017. Each part number has a single HTML file.
.png)
Part-number decode
| Segment | Meaning | This SKU |
|---|---|---|
| Family | RAEGuard 2 PID / FGM-200X | H |
| Type | Instrument / accessory / consumable / spare | Instrument |
| English-list group | Instrument / Accessories / Consumables & Spares | Instrument |
| Model | FGM-2001 / FGM-2002 | FGM-2002 |
| Sampling | Diffusion / Flow-through | Flow-through |
| Range | 0.01–100 / 0.1–1000 / 1–1000 ppm | 0.1–1000 ppm |
| Approval | ATEX/IECEx, UL, Russia, China | Russia |
| This SKU | Kit, RAEGuard 2 PID, Russia, 0.1 – 1000 ppm isobutylene equivalent | H-D03-0005-R00 |
Technical specifications
| Category | RAEGuard 2 PID instrument kit |
|---|---|
| Model | FGM-2002 / Flow-through |
| Approval | Russia |
| Gas | VOC / TVOC,10.6 eV PID |
| Range | 0.1–1000 ppm |
| Resolution | 0.1 ppm |
| Power | 10–28 VDC,约 210 mA@24 V,< 5 W |
| Output | 4–20 mA + RS-485 Modbus + 三路继电器 30 VDC 2 A |
| Entry | 3/4″ NPT M |
| Mounting | 2″ pipe or wall |
| Ingress | IP65 |
| Sensor module | C01-0002-R00 |
Why this part number
Order H-D03-0005-R00 to lock range, sampling and approval: Kit, RAEGuard 2 PID, Russia, 0.1 – 1000 ppm isobutylene equivalent. China D03-*-C00 kits are on product-8017.
What it mates with
H-D03-0005-R00 belongs to Instrument. The kit includes the head and DigiPID.
Typical applications
Refineries, solvent recovery, coating, wastewater, power plants and ambient VOC monitoring.
Selection contrast
| P/N | Type | Description |
|---|---|---|
| H-D03-0002-000 | Instrument | Kit, RAEGuard 2 PID, DIFF, 0.1 – 1000 ppm, FGM-2002, ATEX/IECEx |
| H-D03-0016-000 | Instrument | Kit, RAEGuard 2 PID, DIFF, 0.1 – 1000 ppm, FGM-2002, UL |
| H-D03-0004-000 | Instrument | Kit, RAEGuard 2 PID, ATEX/IECEx, 0.01 – 100 ppm isobutylene equivalent,Flow-through |
| H-D03-0005-000 | Instrument | Kit, RAEGuard 2 PID, ATEX/IECEx, 0.1 – 1000 ppm isobutylene equivalent,Flow-through |
| H-D03-0009-000 | Instrument | Kit, RAEGuard 2 PID, UL, 0.01 – 100 ppm isobutylene equivalent,Flow-through |
| H-D03-0010-000 | Instrument | Kit, RAEGuard 2 PID, UL, 0.1 – 1000 ppm isobutylene equivalent,Flow-through |
| H-D03-0008-000 | Instrument | Kit, RAEGuard 2 PID, ATEX/IECEx, 1 – 1000 ppm isobutylene equivalent,Flow-through Note: Co |
Installation and service
Mount H-D03-0005-R00 on a 2″ pipe or wall, 3/4″ NPT M entries. Power 10–28 VDC. Sensor pointing down. Flow-through water trap on inlet IN. Two-point cal with isobutylene.
FAQ
- Detection principle?
- Photoionization PID at 10.6 eV — not IR, not catalytic.
- Relation to product-8017 D03-*-C00?
- 8017 is the China-list detector. This page uses English-list H-D03-* kits. Existing China SKUs link to 8017 pages.
- 1–1000 vs 0.1–1000 ppm?
- The 1–1000 ppm module disables CFs and relays. Use 0.01–100 or 0.1–1000 ppm if you need gas library or interlocks.
- Substitute the PID lamp?
- No. DigiPID needs the specified MARK2 10.6 eV lamp and PTFE O-ring.
- Diffusion vs Flow Through?
- Do not mix weather/pretreatment/dryer kits; those are Flow Through only.
Documents
English datasheet · Combined Manual Rev H · TVOC gas table · product-9019 · product-8017
Availability and enquiry
Availability: Not in stock — orders accepted; lead time approx. 8 weeks. Quote full P/N H-D03-0005-R00, gas/range and approval.