H-D03-0004-R00 | RAEGuard 2 PID Instrument

H-D03-0004-R00 is a RAE Hua Rui RAEGuard 2 PID instrument kit (FGM-2001, Flow-through, 0.01–100 ppm, Russia). 10–28 VDC, 4–20 mA and RS-485 Modbus, magnetic-wand service.

English-list hub: product-9019. China-list hub: product-8017. Each part number has a single HTML file.

H-D03-0004-R00 Kit, RAEGuard 2 PID, Russia, 0.01 – 100 ppm isobutylene equivalent
RAEGuard 2 PID · H-D03-0004-R00

Part-number decode

SegmentMeaningThis SKU
FamilyRAEGuard 2 PID / FGM-200XH
TypeInstrument / accessory / consumable / spareInstrument
English-list groupInstrument / Accessories / Consumables & SparesInstrument
ModelFGM-2001 / FGM-2002FGM-2001
SamplingDiffusion / Flow-throughFlow-through
Range0.01–100 / 0.1–1000 / 1–1000 ppm0.01–100 ppm
ApprovalATEX/IECEx, UL, Russia, ChinaRussia
This SKUKit, RAEGuard 2 PID, Russia, 0.01 – 100 ppm isobutylene equivalentH-D03-0004-R00

Technical specifications

CategoryRAEGuard 2 PID instrument kit
ModelFGM-2001 / Flow-through
ApprovalRussia
GasVOC / TVOC,10.6 eV PID
Range0.01–100 ppm
Resolution0.01 ppm
Power10–28 VDC,约 210 mA@24 V,< 5 W
Output4–20 mA + RS-485 Modbus + 三路继电器 30 VDC 2 A
Entry3/4″ NPT M
Mounting2″ pipe or wall
IngressIP65
Sensor moduleC01-0001-R00

Why this part number

Order H-D03-0004-R00 to lock range, sampling and approval: Kit, RAEGuard 2 PID, Russia, 0.01 – 100 ppm isobutylene equivalent. China D03-*-C00 kits are on product-8017.

What it mates with

H-D03-0004-R00 belongs to Instrument. The kit includes the head and DigiPID.

Typical applications

Refineries, solvent recovery, coating, wastewater, power plants and ambient VOC monitoring.

Selection contrast

P/NTypeDescription
H-D03-0001-000InstrumentKit, RAEGuard 2 PID, DIFF, 0.01 – 100 ppm, FGM-2001, ATEX/IECEx
H-D03-0015-000InstrumentKit, RAEGuard 2 PID, DIFF, 0.01 – 100 ppm, FGM-2001, UL
H-D03-0004-000InstrumentKit, RAEGuard 2 PID, ATEX/IECEx, 0.01 – 100 ppm isobutylene equivalent,Flow-through
H-D03-0005-000InstrumentKit, RAEGuard 2 PID, ATEX/IECEx, 0.1 – 1000 ppm isobutylene equivalent,Flow-through
H-D03-0009-000InstrumentKit, RAEGuard 2 PID, UL, 0.01 – 100 ppm isobutylene equivalent,Flow-through
H-D03-0010-000InstrumentKit, RAEGuard 2 PID, UL, 0.1 – 1000 ppm isobutylene equivalent,Flow-through
H-D03-0008-000InstrumentKit, RAEGuard 2 PID, ATEX/IECEx, 1 – 1000 ppm isobutylene equivalent,Flow-through Note: Co

Family matrix

Installation and service

Mount H-D03-0004-R00 on a 2″ pipe or wall, 3/4″ NPT M entries. Power 10–28 VDC. Sensor pointing down. Flow-through water trap on inlet IN. Two-point cal with isobutylene.

FAQ

Is H-D03-0004-R00 an IR head?
No. It is a 10.6 eV PID. Host is flameproof; DigiPID is intrinsically safe.
1–1000 vs 0.1–1000 ppm?
The 1–1000 ppm module disables CFs and relays. Use 0.01–100 or 0.1–1000 ppm if you need gas library or interlocks.
Relation to product-8017 D03-*-C00?
8017 is the China-list detector. This page uses English-list H-D03-* kits. Existing China SKUs link to 8017 pages.
Outputs?
3-wire 4–20 mA, RS-485 Modbus, three dry relays. Optional HART 3006-6744-001.

Documents

English datasheet · Combined Manual Rev H · TVOC gas table · product-9019 · product-8017

Availability and enquiry

Stock is lot-based. If H-D03-0004-R00 is short, jump from the family matrix — do not leave a blank P/N.