Honeywell XNX XNX-UTAV-RNIC1 – MPD IR carbon dioxide 0–5 %v/v, mV, UL, Aluminium, 3/4" NPT
XNX-UTAV-RNIC1 is a factory-configured Honeywell XNX with MPD infrared carbon dioxide 0–5 %v/v, mV personality, UL / cUL, 4 × 3/4" NPT, LM25 aluminium (painted), 3 relays + 4–20 mA HART, no local HART port. Use it on beverage carbonation, inerting cabinets and fermenter headspace—not as a toxic ppm cell.
Same sensor, swap enclosure/approval: aluminium XNX-UTAV-RNIC1, 316SS XNX-UTSV-RNIC1, other approval XNX-AMAV-RNIC1. XNX-UTAV-RNIC1 · XNX-UTSV-RNIC1 · XNX-AMAV-RNIC1

Part-number decode
| Segment | Meaning | This SKU |
|---|---|---|
| XNX | Honeywell XNX universal transmitter | XNX |
| A / U | Approval A=ATEX/IECEx; U=UL/cUL | U |
| M / T | Entry M=M25; T=3/4" NPT | T |
| A / S | Enclosure A=aluminium; S=316SS | A |
| V / I / E | Personality V=mV(MPD); I=IR Optima/Excel; E=EC | V |
| N / R / M / F | Option N=HART only; R=relays; M=Modbus; F=FFB | R |
| N / H | Local HART port N=no; H=yes | N |
| IC1 | MPD IR carbon dioxide 0–5 %v/v | IC1 |
Same sensor, swap enclosure/approval: aluminium XNX-UTAV-RNIC1, 316SS XNX-UTSV-RNIC1, other approval XNX-AMAV-RNIC1.
Technical specifications
| Category | Transmitter Configured |
|---|---|
| Personality | mV personality (MPD catalytic / MPD IR) |
| Sensor / range | MPD IR carbon dioxide 0–5 %v/v |
| Target | CO₂ / carbon dioxide |
| Principle | MPD infrared (CO₂) |
| Output | 3 relays + 4–20 mA HART |
| Local HART | no local HART port |
| Supply | 16–32 VDC (24 VDC nominal) |
| Enclosure | LM25 aluminium (painted) |
| Entries | 4 × 3/4" NPT |
| Display | Backlit LCD, magnetic-wand menus |
| Ingress | IP66 |
| Approvals | UL / cUL |
| Temperature | −40~+65 ℃ |
| Mass | approx. 2.8 kg |
| Mates with | Honeywell MPD catalytic bead or MPD infrared sensors |
Why this personality / sensor
CO₂ is heavier than air and fills cellars from the floor up. Percent-level CO₂ is an IR measurement; an electrochemical toxic cell cannot span 5 %vol. Mount 300 mm above the lowest floor and keep the optical path off wet drains.
Personality and replaceable parts
XNX-UTAV-RNIC1 uses the mV personality (MPD catalytic / MPD IR) board and mates with Honeywell MPD catalytic bead or MPD infrared sensors. Factory-fitted with MPD IR carbon dioxide 0–5 %v/v. Spares live on product-3991. Do not substitute Sensepoint XCD cartridges on XNX.
Typical applications
Soft-drink carbonation, brewery cellars and CO₂-inerted cabinets need a 5 %vol trip before asphyxiation. XNX provides the hard-wired extract start; a portable wand is only a leak survey tool.
Selection contrast
| P/N | Gas | Range | Option | Body |
|---|---|---|---|---|
| XNX-UTSV-RNIC1 | CO₂ | 0–5 %v/v | Relays | 316SS |
| XNX-AMAV-RNIC1 | CO₂ | 0–5 %v/v | Relays | Aluminium |
| XNX-UTAV-RNCB1 | LEL | 0–100 %LEL | Relays | Aluminium |
| XNX-UTAV-RNIV1 | CH₄ | 0–100 %LEL | Relays | Aluminium |
| XNX-UTAV-RNIF1 | C₃H₈ | 0–100 %LEL | Relays | Aluminium |
| XNX-UTAV-RNNNN | body | — | Relays | Aluminium |
| XNX-UTAV-NNIC1 | CO₂ | 0–5 %v/v | HART | Aluminium |
Installation and wiring
Wall-mount XNX-UTAV-RNIC1 (LM25 aluminium (painted), approx. 2.8 kg) on a rigid stand sized for that mass. This SKU uses 4 × 3/4" NPT entries—glands must match; do not retap XNX-UTAV-RNIC1. Land XNX-UTAV-RNIC1 4–20 mA HART per the loop drawing; relays/Modbus/FFB exist only on the matching option board. Magnetic-wand menus on the XNX-UTAV-RNIC1 lid stay non-intrusive. XNX-UTAV-RNIC1 5 %v/v CO₂ hugs the cellar floor.
FAQ
- Is XNX-UTAV-RNIC1 a toxic ppm CO₂ detector?
- No. XNX-UTAV-RNIC1 is 0–5 %v/v IR for asphyxiation / inerting. ppm indoor-air CO₂ is a different instrument class.
- Should I mount XNX-UTAV-RNIC1 high or low?
- Low. CO₂ is heavier than air. Keep XNX-UTAV-RNIC1 about 300 mm above the lowest floor, not at the roof ridge.
- When should I swap XNX-UTAV-RNIC1 aluminium for 316SS?
- Use XNX-UTAV-RNIC1 (aluminium, ~2.8 kg) in inland, painted plant. Coastal, splash and sour-water decks should move to stainless sibling XNX-UTSV-RNIC1.
- Why is XNX-UTAV-RNIC1 NPT instead of M25?
- XNX-UTAV-RNIC1 is the UL/cUL body and ships 3/4" NPT. Do not tap M25 on this lid—order ATEX sibling XNX-AMAV-RNIC1 if metric glands are mandatory.
- What do the three relays on XNX-UTAV-RNIC1 do?
- XNX-UTAV-RNIC1 adds three configurable relays on top of 4–20 mA HART—typically A1/A2/fault. It is not Modbus; bus siblings are XNX-UTAV-MNIC1 / XNX-UTAV-FNIC1.
Documents
Honeywell XNX datasheet / manual · On-site XNX selection matrix
Availability and enquiry
Stock is lot-based. If this box is out, jump to 316SS XNX-UTSV-RNIC1 or UL XNX-UTAV-RNIC1 rather than a dead SKU.