Honeywell XNX XNX-UTAV-RNCB1 – MPD catalytic 0–100 %LEL, mV, UL, Aluminium, 3/4" NPT

XNX-UTAV-RNCB1 is a factory-configured Honeywell XNX gas detector: mV personality, MPD catalytic bead 0–100 %LEL, UL / cUL, 4 × 3/4" NPT, LM25 aluminium (painted), 3 relays + 4–20 mA HART, no local HART port. Specify it for mixed hydrocarbon LEL points where infrared windows would fog or the stream is not methane/propane-specific.

Same sensor, swap enclosure/approval: aluminium XNX-UTAV-RNCB1, 316SS XNX-UTSV-RNCB1, other approval XNX-AMAV-RNCB1. XNX-UTAV-RNCB1 · XNX-UTSV-RNCB1 · XNX-AMAV-RNCB1

XNX-UTAV-RNCB1 Honeywell XNX flammable gas (catalytic) Aluminium 3/4" NPT

Part-number decode

SegmentMeaningThis SKU
XNXHoneywell XNX universal transmitterXNX
A / UApproval A=ATEX/IECEx; U=UL/cULU
M / TEntry M=M25; T=3/4" NPTT
A / SEnclosure A=aluminium; S=316SSA
V / I / EPersonality V=mV(MPD); I=IR Optima/Excel; E=ECV
N / R / M / FOption N=HART only; R=relays; M=Modbus; F=FFBR
N / HLocal HART port N=no; H=yesN
CB1MPD catalytic 0–100 %LELCB1

Same sensor, swap enclosure/approval: aluminium XNX-UTAV-RNCB1, 316SS XNX-UTSV-RNCB1, other approval XNX-AMAV-RNCB1.

Technical specifications

CategoryTransmitter Configured
PersonalitymV personality (MPD catalytic / MPD IR)
Sensor / rangeMPD catalytic 0–100 %LEL
TargetLEL / flammable gas (catalytic)
PrincipleMPD catalytic bead
Output3 relays + 4–20 mA HART
Local HARTno local HART port
Supply16–32 VDC (24 VDC nominal)
EnclosureLM25 aluminium (painted)
Entries4 × 3/4" NPT
DisplayBacklit LCD, magnetic-wand menus
IngressIP66
ApprovalsUL / cUL
Temperature−40~+65 ℃
Massapprox. 2.8 kg
Mates withHoneywell MPD catalytic bead or MPD infrared sensors

Why this personality / sensor

A poison-resistant MPD pellistor sees combustion heat across a wide hydrocarbon mix, including species an IR filter misses. It needs oxygen and hates silicones. Mount above light-gas releases and below heavy vapours; keep silicone sealants off the sinter.

Personality and replaceable parts

XNX-UTAV-RNCB1 uses the mV personality (MPD catalytic / MPD IR) board and mates with Honeywell MPD catalytic bead or MPD infrared sensors. Factory-fitted with MPD catalytic 0–100 %LEL. Spares live on product-3991. Do not substitute Sensepoint XCD cartridges on XNX.

Typical applications

Pump rooms, filling gantries and compressor packages still standardise on catalytic LEL because the gas slate is mixed. XNX holds 4–20 mA HART into the ESD matrix; magnetic non-intrusive calibration keeps the flameproof lid closed.

Selection contrast

P/NGasRangeOptionBody
XNX-UTSV-RNCB1LEL0–100 %LELRelays316SS
XNX-AMAV-RNCB1LEL0–100 %LELRelaysAluminium
XNX-UTAV-RNIV1CH₄0–100 %LELRelaysAluminium
XNX-UTAV-RNIF1C₃H₈0–100 %LELRelaysAluminium
XNX-UTAV-RNIC1CO₂0–5 %v/vRelaysAluminium
XNX-UTAV-RNNNNbodyRelaysAluminium
XNX-UTAV-NNCB1LEL0–100 %LELHARTAluminium

XNX family matrix

Installation and wiring

Wall-mount XNX-UTAV-RNCB1 (LM25 aluminium (painted), approx. 2.8 kg) on a rigid stand sized for that mass. This SKU uses 4 × 3/4" NPT entries—glands must match; do not retap XNX-UTAV-RNCB1. Land XNX-UTAV-RNCB1 4–20 mA HART per the loop drawing; relays/Modbus/FFB exist only on the matching option board. Magnetic-wand menus on the XNX-UTAV-RNCB1 lid stay non-intrusive. Keep silicones off the XNX-UTAV-RNCB1 pellistor; light hydrocarbons high, heavy vapours low.

FAQ

Will silicone vapours kill the XNX-UTAV-RNCB1 pellistor?
Yes. Silicones and chlorinated solvents poison the MPD catalytic bead on XNX-UTAV-RNCB1. Specify IV1/IF1 infrared if those contaminants are routine.
What bump-test gas should I use on XNX-UTAV-RNCB1?
Use the target hydrocarbon at 50 %LEL. Methane-only test gas will under-state response if the process is petrol vapour.
When should I swap XNX-UTAV-RNCB1 aluminium for 316SS?
Use XNX-UTAV-RNCB1 (aluminium, ~2.8 kg) in inland, painted plant. Coastal, splash and sour-water decks should move to stainless sibling XNX-UTSV-RNCB1.
Why is XNX-UTAV-RNCB1 NPT instead of M25?
XNX-UTAV-RNCB1 is the UL/cUL body and ships 3/4" NPT. Do not tap M25 on this lid—order ATEX sibling XNX-AMAV-RNCB1 if metric glands are mandatory.
What do the three relays on XNX-UTAV-RNCB1 do?
XNX-UTAV-RNCB1 adds three configurable relays on top of 4–20 mA HART—typically A1/A2/fault. It is not Modbus; bus siblings are XNX-UTAV-MNCB1 / XNX-UTAV-FNCB1.

Documents

Honeywell XNX datasheet / manual · On-site XNX selection matrix

Availability and enquiry

Stock is lot-based. If this box is out, jump to 316SS XNX-UTSV-RNCB1 or UL XNX-UTAV-RNCB1 rather than a dead SKU.

WhatsAppTop