Honeywell Searchpoint Optima Plus OPTIMACALKIT-REG – Calibration: Optima Plus Pressure Regulator for calibration gas cylinder
OPTIMACALKIT-REG is a Searchpoint Optima Plus Calibration: Optima Plus Pressure Regulator for calibration gas cylinder. It is not a gas detector body and will not detect LEL on its own. Order this SKU for maintenance, calibration or mounting; the head remains a 2108N transmitter number.
OPTIMACALKIT-REG is a Calibration; see same-class SKUs in the matrix.

Part-number decode
| Segment | Meaning | This SKU |
|---|---|---|
| Family | Honeywell Searchpoint Optima Plus point IR | Optima Plus |
| P/N | Optima Plus Pressure Regulator for calibration gas cylinder | OPTIMACALKIT-REG |
| Class | Accessory | Calibration |
Technical specifications
| Category | Accessory / Calibration |
|---|---|
| Description | Optima Plus Pressure Regulator for calibration gas cylinder |
| Gas | — |
| Output | — |
| Approvals | see description |
| Entries | — |
| Enclosure | — |
| RGC | — |
| Principle | Point IR (dual source, dual beam) |
| Range | — |
| Ingress | 随本体 |
Why this part number
Keep OPTIMACALKIT-REG on its own BOM line so windows, lamps, PCBs, glands and brackets can be replaced on their own cycle. Do not bury it under 2108N4000N, and do not fit XCD or XNX spares on Optima optics.
Spares and mates
OPTIMACALKIT-REG is Searchpoint Optima Plus Calibration. This SKU is a spare or accessory and needs an Optima Plus detector. Matrix: product-2698. Do not substitute Sensepoint XCD cartridges or XNX personalities.
Typical applications
Use OPTIMACALKIT-REG against installed Optima Plus points: dust barriers after deluge, flow housings on extractive loops, cups and cylinders at annual gas. Match the detector thread (M20 vs NPT) before the box ships.
Selection contrast
| P/N | Type | Gas | Cert | Output |
|---|---|---|---|---|
| 2108B0280 | Calibration | — | — | — |
| 2108B0283 | Calibration | — | — | — |
| 2108B0284 | Calibration | — | — | — |
| 2108B0285 | Calibration | — | — | — |
| OPTIMACALKIT | Calibration | — | — | — |
| OPTIMACALKIT-HC | Calibration | Hydrocarbon | — | — |
| OPTIMACALKIT-ET | Calibration | Ethylene | — | — |
Installation and service
Isolate power before swapping OPTIMACALKIT-REG. Refit seals to the specified torque and keep M20/M25/NPT families apart. Zero and span afterwards; keep fingerprints and condensation off the optics.
FAQ
- Housing/approval?
- Match Ex and material requirements to the P/N.
- Which detector does OPTIMACALKIT-REG mate with?
- New builds: current 2108N SKUs such as 2108N4000N. Installed base: read the 2108B/2108N nameplate first.
- Vs Searchline Excel?
- Optima is point IR; Excel is open-path.
- Enquiry?
- Quote full P/N OPTIMACALKIT-REG plus approval/interface.
- Rescale on site?
- Follow the manual/ordered config; re-order if needed.
Documents
Optima Plus datasheet 1 · Datasheet 2 · On-site part-number matrix
Availability and enquiry
Availability: Not in stock — orders accepted; lead time approx. 12 weeks. Quote full P/N OPTIMACALKIT-REG, gas/range and approval.